Quote: Why is the third hand on the watch called the second hand?


Page Index Toggle Pages: 1
Send Topic Print
connect two 2 lamp T8 ballasts (Read 2759 times)
DiverDoc
GDPR opt-out









connect two 2 lamp T8 ballasts
Jul 20th, 2010, 4:10pm
 
Greetings electrical gurus!

I would appreciate some assistance:

I am upgrading a 4 four foot T12 bulb 2 magnetic ballast fixture to contain T8 bulbs and new electronic ballasts. In the fixture, one ballast powered the inner two bulbs and the other the outer two bulbs.

Problem:

I brought the ballasts home tonight and found they lack all the wires my old ballasts had.

These are Sylvania Quicktronic QTP 2X32T8/UNV ISN-SC ballasts.

They have on one end a red and a white wire, and on the other, two blue wires.

How do I wire the two ballasts to power the sockets? I have the usual one white and one black power wires entering the ceiling fixture.

I would sure appreciate some guidance.

Thanks!
Back to top
 
 
IP Logged
 
plugwash
Administrator
*****
Offline

I love YaBB 1G - SP1!

Posts: 1383


Total Thanks: 0
For This Post: 0



Trade: Not Specified

Re: connect two 2 lamp T8 ballasts
Reply #1 - Jul 22nd, 2010, 11:20am
 
hmm accroding to the manual I found that ballest should have a black and white for power input, a red that goes to one end of each tube ( http://assets.sylvania.com/assets/documents/PIB_T8_%20IS_10_THD_UNV.30d93ddc-2f4... ) and two blues which go the the other end of each of the two tubes.