I,ve been quoted £400-£950 by 4 different companies to Powerflush my 9 Rad system???
WTF?? why so costly..OK its a days work...sort of...Surely this is a major Rip Off???
(I work as PC repair)....It can take sometimes 10hrs+ to remove virus,s etc from machine by scanning....but I couldn't charge the same price
Any comments, suggestions...Thanx
Back to top
IP Logged
thescruff
Global Moderator
Trade Member
Author
Offline
Who said plumbing was
easy.
Posts: 6037
Total Thanks: 147
For This Post: 0
Gender:
Trade: Plumber
Re: POWERFLUSH CENTRAL HEATING SYSTEM
Reply #1 -
Oct 4
th
, 2010, 11:59pm
£400.00 is a realistic price from an independent, £950.00 is a BG price and yes as you say a rip off.
Back to top
IP Logged
londonman
Trade Member
Offline
I love YaBB 1G - SP1!
Posts: 1697
Total Thanks: 13
For This Post: 0
Malvern
United Kingdom
Trade: Cabinet Maker
Re: POWERFLUSH CENTRAL HEATING SYSTEM
Reply #2 -
Oct 5
th
, 2010, 8:36am
Having just gone through the hassle of using one myself, that is one option for you to consider...ie hire one. Why do you think you need one?
Back to top
«
Last Edit: Oct 5
th
, 2010, 8:36am by londonman
»
Would all Third Party Apologists kindly mind their own business .....
IP Logged
CWatters
Super Member
Offline
"Daddy fick it" says James
Posts: 5150
Total Thanks: 58
For This Post: 0
Gender:
Re: POWERFLUSH CENTRAL HEATING SYSTEM
Reply #3 -
Oct 5
th
, 2010, 3:31pm
and when you're done remember to put corrosion inhibitor in to help stop sludge building up. Few boiler care/service plans include checking the corrosion inhibitor concentration. I can't help feel you've just found out why.
Back to top
IP Logged
TonyElyod
GDPR opt-out
Total Thanks: 58
For This Post: 0
Re: POWERFLUSH CENTRAL HEATING SYSTEM
Reply #4 -
Oct 10
th
, 2010, 6:18pm
Advised to power flush Cos the boiler turns off after 10 secs & NO rads get warm.
Has had New diverter Valve...New Pump..New thermister fitted without joy
Can I do it with hosepipe from CW or do I need to hire specialist gear??
Back to top
«
Last Edit: Oct 10
th
, 2010, 6:22pm by TonyElyod
»
IP Logged
CWatters
Super Member
Offline
"Daddy fick it" says James
Posts: 5150
Total Thanks: 58
For This Post: 0
Gender:
Re: POWERFLUSH CENTRAL HEATING SYSTEM
Reply #5 -
Oct 10
th
, 2010, 8:29pm
If the system is so heavily blocked that the boiler is shutting down then putting cleaner in is unlikely to work. It needs to be circulated around the system to work.
Back to top
IP Logged
thescruff
Global Moderator
Trade Member
Author
Offline
Who said plumbing was
easy.
Posts: 6037
Total Thanks: 147
For This Post: 0
Gender:
Trade: Plumber
Re: POWERFLUSH CENTRAL HEATING SYSTEM
Reply #6 -
Oct 10
th
, 2010, 9:25pm
Sounds more like the plate HX is blocked, assuming it's a combi.
Back to top
IP Logged
Pages: 1
(Moderator: thescruff) - (Moderator Group: Board Moderator)
<
Previous Topic
|
Next Topic
>
Ask The Trades
›
DIY Forum
›
Plumbing Questions
› POWERFLUSH CENTRAL HEATING SYSTEM
Forum Jump »
Home
» 10 most recent Posts
» 10 most recent Topics
DIY Forum
- Electrical Questions
- Plumbing Questions ««
- Carpentry Questions
- Building Questions
- Painting, Decorating & Tiling Questions
- Alarms, Phones, Aerials, CCTV & Datacomms
Public Forum
- Just Talk
- Humour
- The Forum
- Trade Applications
Ask The Trades
» Powered by
YaBB 2.3
!
YaBB
© 2000-2008. All Rights Reserved.