BAXI 105 HE FLAME FAILURE (Read 2645 times)
raynos
GDPR opt-out









BAXI 105 HE FLAME FAILURE
Nov 28th, 2010, 3:50pm
 
HI IVE HAD NO HEATING OR HOT WATER FRO OVER A WEEK NOW.

FLAME FAILURE NEON FLASHES.

STARTS UP, IGNITES, ATTEMPTS FOR 10 SECONDS BEFORE ABORTING.
TRIES TWICE MORE BEFORE FAILING AND NEON FLASHES.

REPLACED PCB, MICROSWITCHES, GAS SENSORS, SELECTOR SWITCH  COUPLE OF ISOTHERMS, FLUE STAT, WITH SAME RESULT EVERYTIME.

PRESSURE IS AT 1.5 NO PROBLEM PRIOR TO THIS.

PLEASE HELP ITS FREEZING!!!!
Back to top
« Last Edit: Nov 28th, 2010, 3:58pm by raynos »  
 
IP Logged
 
tomplum
GDPR opt-out









Re: BAXI 105 HE FLAME FAILURE
Reply #1 - Dec 1st, 2010, 9:15pm
 
air pressure switch is a common cause of this problem,
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: BAXI 105 HE FLAME FAILURE
Reply #2 - Dec 2nd, 2010, 12:06am
 
Have you checked the condensate pipe is not frozen.  Grin
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
greg
Re: BAXI 105 HE FLAME FAILURE
Reply #3 - Dec 11th, 2010, 8:06pm
 
With all the bits youve thrown at it without success would have been cheaper to get a RGI in to look at it