Dec 15th, 2010, 8:44pm
 
my wonderful (far from) ideal isar he 30 has problems again.  Sad

working fine this morning, now hot water fine but no central heating boiler is running all the time and showing the d symbol just no heat what so ever.  showing just over 1bar.

What could be the cause this time? any ideas?
Back to top
 

All advice is at least two years out of date.
Thank User For This Post View members image gallery  
IP Logged
 
greg
Re: Ideal isar he 30 no CH
Reply #1 - Dec 16th, 2010, 7:29pm
 
Diverter valve stuck in DHW
Back to top
 
Thank User For This Post  
IP Logged
 
wozzy
Trade Member
*****
Offline

Ask The Trades
Posts: 584


Total Thanks: 4
For This Post: 0


Gender: male

Trade: Electrician



Re: Ideal isar he 30 no CH
Reply #2 - Dec 16th, 2010, 8:53pm
 
thanks for the reply.

i did consider whether to post this or not but may as well make a arse of myself.

the reason for no heating at all was in fact a tap had been left on.  Very very slowly a bath tap, i have a posh bath so the water doesnt drop but trickles down the bath, i must have knocked it at some point.  

That trickle meant i had no heating.  Are all combis this good?


try not to laugh too hard at this one i can assure u i wasnt then i reasiled!
Back to top
 

All advice is at least two years out of date.
Thank User For This Post View members image gallery  
IP Logged
 
greg
Re: Ideal isar he 30 no CH
Reply #3 - Dec 17th, 2010, 7:38am
 
Your not the first and wont be the last.  All combis give priority to DHW, so long as the flow is enough to operate the flow switch then you ave your scenario.

Glad it was an easy fix though  Wink
Back to top
 
Thank User For This Post  
IP Logged
 
wozzy
Trade Member
*****
Offline

Ask The Trades
Posts: 584


Total Thanks: 4
For This Post: 0


Gender: male

Trade: Electrician



Re: Ideal isar he 30 no CH
Reply #4 - Dec 17th, 2010, 7:37pm
 
i just never imagined a small trickle would stop the heating completely!  Roll Eyes