Can you have 'flow' without 'pressure'?
Dec 29th, 2010, 1:41pm
 
I don't think that you can however, part of the defence case for the builders merchants I am suing for damage caused by their Powerflush unit, is that a satisfactory pre-inspection test by them is to test the connections for tightness by pulling on them - because the unit works on 'flow' and not 'pressure'.

Sounds like bollocks to me.
Back to top
« Last Edit: Dec 29th, 2010, 1:42pm by londonman »  

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Can you have 'flow' without 'pressure'?
Reply #1 - Dec 29th, 2010, 2:17pm
 
A heating pump, is actually a circulator, they work by displacing water in the circuit, however, there has to be a build up of pressure to move water from A to B.

There are several types of flushing kits, and you need to say what type you had, for example, as above a circulator displaces water, from A to B, but a flushing machine, takes water from C, pushes it down A and B goes back in the bucket, so it's not displacing water and a different kettle of fish.

A simple answer is yes there must be a build up of pressure, from the velocity.

Don't know if I can find a pic from years ago, but it shows a circulator with pressure gauges, and nearly 1bar differential between the inlet and outlet.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
londonman
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 1697


Total Thanks: 13
For This Post: 0


Malvern, United Kingdom
Malvern
United Kingdom


Trade: Cabinet Maker

Re: Can you have 'flow' without 'pressure'?
Reply #2 - Dec 29th, 2010, 6:07pm
 
It was this one.

http://www.kamco.co.uk/cf30kit.htm

Connects into the ch system by removing the ch pump and replacing with the pipes from this unit. My understanding is that the pump in this unit will create pressure to push the water round the central heating system and then into the reservoir at the bottom.

Can you confirm that if say radiator A was flowing freely but when this was turned off and radiator B turned on (radiator B being very badly blocked) that the pressure in the system between the pump in the unit and radiator B flow would increase.
Back to top
 

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Can you have 'flow' without 'pressure'?
Reply #3 - Dec 29th, 2010, 11:42pm
 
You can't have flow without pressure but that's all a red herring.

The proper proceedure for testing the unit is detailed in the manual....

http://www.kamco.co.uk/GuidanceNotes/PDF/FlowCheck.pdf

Selected quote..

Quote:
8. Attach the pressure gauge into the hose end and turn the motor on for 30 seconds. While the motor is running you should get a reading of 19-21PSI


I would expect a hire center to use the manufacturers recommended test proceedure especially as..

Quote:
These are not time consuming, do not require a high level of expertise and will not invalidate the warranty.


No mention of testing connections by simply "pulling on them". Well ok it does say to check the connections as well but you know what I mean.


Back to top
« Last Edit: Dec 29th, 2010, 11:49pm by CWatters »  
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Can you have 'flow' without 'pressure'?
Reply #4 - Dec 30th, 2010, 1:22am
 
You should always open rad B before you close rad A.

Anyway you have the pressure from the pdf CWatters posted 19-21psi  Smiley

Thats 1.38 bar ish which is about what I expected.
Back to top
« Last Edit: Dec 30th, 2010, 1:23am by thescruff »  
Thank User For This Post View members image gallery  
IP Logged
 
londonman
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 1697


Total Thanks: 13
For This Post: 0


Malvern, United Kingdom
Malvern
United Kingdom


Trade: Cabinet Maker

Re: Can you have 'flow' without 'pressure'?
Reply #5 - Dec 30th, 2010, 12:41pm
 
Thanks chaps.
Back to top
 

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Can you have 'flow' without 'pressure'?
Reply #6 - Dec 30th, 2010, 2:40pm
 
The problem you are likely to have is proving you did cause the hose to come off.

In my opinion you could be fighting a loosing battle.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
greg
Re: Can you have 'flow' without 'pressure'?
Reply #7 - Dec 31st, 2010, 1:16pm
 
How did the hose come off?  The hose threads onto the machine against a washer, so you'll get leakage from the connection, tighten up jobs a good un, or have they changed the way you connect the CF30 hoses, mine is about 4/5 years old now.
Back to top
 
Thank User For This Post  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print