Wayne B
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #17 - Mar 6th, 2011, 2:54pm
 
The Stat on a 27" Immersion Heater is 18" it usualy fits the 30" and 36" as well.
It may also be worth looking up the manufacturer of the cylinder to see what they recomend be fitted.
Back to top
 
 
IP Logged
 
mike52
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #18 - Mar 6th, 2011, 3:07pm
 
Quote:
The Stat on a 27" Immersion Heater is 18" it usualy fits the 30" and 36" as well.
It may also be worth looking up the manufacturer of the cylinder to see what they recomend be fitted.


I will try to check with the plumber to see what he put in and also check with the mnufacturer - won't be until tomorrow though as it's Sunday.

Can you see anything obvious from the photo's I posted?

Thanks

Mike
Back to top
 
 
IP Logged
 
Wayne B
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #19 - Mar 6th, 2011, 3:13pm
 
To me it looks like either the stat in that Heater is too short or the manufacturer may specify a longer Heater and stat.
But would ask them first.
It may be as i say that they want you to fit a longer one?
But would deffo get that stat pulled out of there and if its a 7" stat bingo swap that first.
Back to top
 
 
IP Logged
 
mike52
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #20 - Mar 6th, 2011, 3:15pm
 
Quote:
To me it looks like either the stat in that Heater is too short or the manufacturer may specify a longer Heater and stat.
But would ask them first.
It may be as i say that they want you to fit a longer one?
But would deffo get that stat pulled out of there and if its a 7" stat bingo swap that first.


Thanks Wayne - appreciate your help on this
Back to top
 
 
IP Logged
 
Wayne B
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #21 - Mar 6th, 2011, 3:22pm
 
No worries the plumber will have bought it in good faith but balls ups on parts and bits are more common than you think and even though brand new it may yet be the new immersion heater, and also put the question to the manufacturer of the cylinder what they recomend as ideal for your situation and use.
But get someone to pull that stat out and make sure deffo its not a 7" bud.
Back to top
 
 
IP Logged
 
mike52
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #22 - Mar 6th, 2011, 3:56pm
 
Quote:
No worries the plumber will have bought it in good faith but balls ups on parts and bits are more common than you think and even though brand new it may yet be the new immersion heater, and also put the question to the manufacturer of the cylinder what they recomend as ideal for your situation and use.
But get someone to pull that stat out and make sure deffo its not a 7" bud.


Will do  Smiley
Back to top
 
 
IP Logged
 
mike52
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #23 - Mar 6th, 2011, 4:12pm
 
Quote:
No worries the plumber will have bought it in good faith but balls ups on parts and bits are more common than you think and even though brand new it may yet be the new immersion heater, and also put the question to the manufacturer of the cylinder what they recomend as ideal for your situation and use.
But get someone to pull that stat out and make sure deffo its not a 7" bud.


Just found the end of the box that housed the new immersion and thermostat the plumber put into the tank - he showed it to me to confirm he had put in a 27" element and an 18" thermostat - so I can definetely confirm it's an 18" thermostat and he has swopped it out twice - and the same for the immersion element..

I can understand that parts can get mixed up - but you would have thought that both he (the plumber) and the supplier would both know what particular type of immersion element and thermostat would be right for that tank.. - or am I being naive?  Wink

Back to top
 
 
IP Logged
 
mike52
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #24 - Mar 6th, 2011, 5:09pm
 
Quote:
No worries the plumber will have bought it in good faith but balls ups on parts and bits are more common than you think and even though brand new it may yet be the new immersion heater, and also put the question to the manufacturer of the cylinder what they recomend as ideal for your situation and use.
But get someone to pull that stat out and make sure deffo its not a 7" bud.


Hi again Wayne

Think we have sussed the problem out.. I have just had a friend around who is an electrician - he checked the power into and out of the thermostat again - and guess what.. it's only intermittently working, and then whilst doing it it started arcing inside - so it's definetely a faulty thermostat.. He thinks the suppliers have had a faulty batch - hence the plumber changing it and it still not working properly. I will get another thermostat in the morning and hopefully resolve the problem.  Well, at least I know what it is now!

Thanks for your help - it's been very much appreciated.  Grin

Mike
Back to top
 
 
IP Logged
 
Wayne B
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #25 - Mar 6th, 2011, 7:53pm
 
Bloody knew it LOL Glad your sorted bud Smiley
Back to top
 
 
IP Logged
 
ronb
GDPR opt-out









Re: No hot water from new immersion - help please!!
Reply #26 - Mar 7th, 2011, 8:51pm
 
Hi all this is my idea
as water heats up it causes stratification ( water is hotter at top and temp drops as you get lower down the tank ) because the thermostat is built into the imersion heater element at the top of the tank it will cut out when the water at the top of the tank reaches 60.c whilst the water 1/3 of way down tank may be only 20.c
is it posible to bypass emersion heater thermostat and fit a cylinder stat at 1/3 up from bottom ???
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: No hot water from new immersion - help please!!
Reply #27 - Mar 8th, 2011, 3:59am
 
No.

Buy a Redring immersion heater and stat and try that.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Wayne B
Re: No hot water from new immersion - help please!!
Reply #28 - Mar 8th, 2011, 6:10am
 
Bit late lads it was sorted the other day it was a faulty stat. Smiley
Back to top
 
Thank User For This Post  
IP Logged
 
Wayne B
Re: No hot water from new immersion - help please!!
Reply #29 - Mar 8th, 2011, 6:30am
 
Start simple Ron lol always check basic stuff first before going in there heavy handed bud.
A new stat is only about £6.00 and in this case the guy should get one free from the merchants who supplied the duff one.
Just because something is brand new dont think it cant be faulty is the lesson in this case. Smiley
Back to top
 
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8815


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: No hot water from new immersion - help please!!
Reply #30 - Mar 19th, 2011, 7:53am
 