Baxi 105e Combi problem (Read 4983 times)
MartQ
GDPR opt-out









Baxi 105e Combi problem
Apr 9th, 2011, 10:30am
 
Hi,
I unfortunately have a Baxi Combi 105e (not the direct version).
I replaced the diverter diaphragm about 12 months ago which sorted out my first problem with the hot water.
Recently however it has developed new symptoms:

When a HW tap is on, the boiler fires up no problems so it looks like the diaphragm is still ok, but with the CH OFF at the control/timer switch, the HW only gets luke warm and the CH radiators warm up.

If the CH is on at the timer/control switch, the water gets hot.

There are no fault lights lit.

Any suggestions??
Back to top
 
 
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Baxi 105e Combi problem
Reply #1 - Apr 9th, 2011, 10:37am
 
I'm not trade but... sounds like diverter valve or microswitches on it.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Baxi 105e Combi problem
Reply #2 - Apr 9th, 2011, 12:06pm
 
Sounds like a diverter valve on a dirty system if you replaced it 12 months ago
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
MartQ
Re: Baxi 105e Combi problem
Reply #3 - Apr 10th, 2011, 10:22am
 
Thanks guys, i'll check it out.
Back to top
 
Thank User For This Post  
IP Logged
 
Alan Townend
Re: Baxi 105e Combi problem
Reply #4 - Jul 4th, 2011, 12:22pm
 
Hi Mart,

It looks as though your water is diverting into the heating when the hot tap is turned on, which basically tells us that the diverter valve needs replacing. However, I should seek advice from a competent and Gas Safe Registered engineer.

Regards,
Alan T