Why no Dergo on 1 stack/drain testing? (Read 5574 times)
birty
Trade Member
*****
Offline


Posts: 90


Total Thanks: 0
For This Post: 0


Gender: male

Trade: Electrician



Why no Dergo on 1 stack/drain testing?
May 15th, 2011, 3:34pm
 
Curious why our new self build house has a stack going up through roof (all 3 are internal stacks) and two other stacks have dergo's on them and terminate in bathrooms/ensuite etc?? Why not  dergo's on all 3.
I Have to do a drain test soon- does this mean climbing onto roof with a drain blank and sealing it prior to a testing for leaks?? Can I not simply cut it and put a dergo onto it or does one stack always have to vent to outside air??? Huh
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
greg
Re: Why no Dergo on 1 stack/drain testing?
Reply #1 - May 15th, 2011, 6:33pm
 
Usually head of drain is vented.  You will probably have to do water test rather than an air test.
Back to top
 
Thank User For This Post  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Why no Dergo on 1 stack/drain testing?
Reply #2 - May 16th, 2011, 7:21am
 
Think it's the Building regs. I think the furthest stack from the main sewer (eg the head end) has to be an open ventilated stack. Stacks between that one and the mains sewer can have AAV fitted.

Back to top
« Last Edit: May 16th, 2011, 7:23am by CWatters »  
Thank User For This Post View members image gallery  
IP Logged
 
birty
Trade Member
*****
Offline


Posts: 90


Total Thanks: 0
For This Post: 0


Gender: male

Trade: Electrician



Re: Why no Dergo on 1 stack/drain testing?
Reply #3 - May 16th, 2011, 9:01pm
 
How do you do a water test, remembering that we been in for over a year now and all seems well (and bobed in!!)
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
greg
Re: Why no Dergo on 1 stack/drain testing?
Reply #4 - May 16th, 2011, 9:34pm
 
Bag the drain, flush WC until water backs up to WC rim.  Allow to settle for a few mins, should then hold level if drain is sound.  Remove bag and quickly get out of the way of the rush of water.

Needs to be done on lowest stack connection, ie cloakroom WC if that is the lowest or bathroom / en-suite if that is the lowest etc.
Back to top
 
Thank User For This Post  
IP Logged
 
birty
Trade Member
*****
Offline


Posts: 90


Total Thanks: 0
For This Post: 0


Gender: male

Trade: Electrician



Re: Why no Dergo on 1 stack/drain testing?
Reply #5 - May 17th, 2011, 10:47pm
 
cheers Greg... And if there is a bathroom on 1st floor and a loo on ground floor -the same stack then i assume still the lowest point is to be tested only?? Also is it the norm for Building control to allow a water test??? (All my externals are ok  with an air test- i tried the other day- its just my internals now then i will get BC around once I am happy they will pass...)
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 