Sep 9
th
, 2011, 12:45pm
I have replaced to ceiling light fittings downstair and both had an earth coming out of the ceiling so all connected.
The upstair one has no earth coming out the ceiling, is this ok?
The light switch is plastic.
If an earth is required would this be easily installed as I am assuming I would have easy access in the loft which is where the wiring goes.
thanks
Back to top
Juco
IP Logged
CWatters
Super Member
Offline
"Daddy fick it" says James
Posts: 5150
Total Thanks: 58
For This Post: 0
Gender:
Re: Lighting earth question
Reply #1 -
Sep 9
th
, 2011, 6:50pm
Lights are normally wired using "Twin & Earth" cable. The earth wire in Twin & Earth cable doesn't have it's own insulation on it so if someone in the past has cut it right back you might not notice it's there. Have another look where the live and neutral wires come out of the cable sleeve.
On most
plastic
ceiling roses the incoming earth wire is connected to an outgoing earth (in a terminal block) but it's not actually used by the pendant. If this is the last light on the circuit there is no outgoing cable so it's possible the incoming earth was just incorrectly snipped off.
If you are replacing a pendant with a light that needs an earth then you may have to pull a bit more wire through the hole in the ceiling and strip back the insulation to expose the earth. The exposed copper earth wire needs to be sleeved with green&yellow sleeving before connecting it to the light.
If there isn't enough spare wire in the ceiling a new wire may need to installed.
Back to top
«
Last Edit: Sep 9
th
, 2011, 7:02pm by CWatters
»
IP Logged
baz
Trade Member
Offline
If it ain't broke, keep
fixing it until it is!
Posts: 258
Total Thanks: 0
For This Post: 0
Henley-on-Thames
United Kingdom
Gender:
Trade: Electrician
Re: Lighting earth question
Reply #2 -
Sep 9
th
, 2011, 7:51pm
Just because there is a "earth" conductor does not mean that it is connected to earth. You need to test it once the connections are made otherwise thee is no point.
By the way, the centre unsleeved conductor is called the cpc.
Back to top
Why is it that, when we stumble across a can of worms, instead of running for the door we find ourselves reaching for a can opener?
IP Logged
Pages: 1
(Moderator: Lectrician) - (Moderator Group: Board Moderator)
<
Previous Topic
|
Next Topic
>
Ask The Trades
›
DIY Forum
›
Electrical Questions
› Lighting earth question
Forum Jump »
Home
» 10 most recent Posts
» 10 most recent Topics
DIY Forum
- Electrical Questions ««
- Plumbing Questions
- Carpentry Questions
- Building Questions
- Painting, Decorating & Tiling Questions
- Alarms, Phones, Aerials, CCTV & Datacomms
Public Forum
- Just Talk
- Humour
- The Forum
- Trade Applications
Ask The Trades
» Powered by
YaBB 2.3
!
YaBB
© 2000-2008. All Rights Reserved.