Lighting earth question (Read 2076 times)
juco
Full Member
***
Offline

Ask The Trades
Posts: 183


Total Thanks: 0
For This Post: 0


Gender: male

Lighting earth question
Sep 9th, 2011, 12:45pm
 
I have replaced to ceiling light fittings downstair and both had an earth coming out of the ceiling so all connected.
The upstair one has no earth coming out the ceiling, is this ok?
The light switch is plastic.
If an earth is required would this be easily installed as I am assuming I would have easy access in the loft which is where the wiring goes.

thanks
Back to top
 

Juco
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Lighting earth question
Reply #1 - Sep 9th, 2011, 6:50pm
 
Lights are normally wired using "Twin & Earth" cable. The earth wire in Twin & Earth cable doesn't have it's own insulation on it so if someone in the past has cut it right back you might not notice it's there. Have another look where the live and neutral wires come out of the cable sleeve.

On most plastic ceiling roses the incoming earth wire is connected to an outgoing earth (in a terminal block) but it's not actually used by the pendant. If this is the last light on the circuit there is no outgoing cable so it's possible the incoming earth was just incorrectly snipped off.

If you are replacing a pendant with a light that needs an earth then you may have to pull a bit more wire through the hole in the ceiling and strip back the insulation to expose the earth. The exposed copper earth wire needs to be sleeved with green&yellow sleeving before connecting it to the light.

If there isn't enough spare wire in the ceiling a new wire may need to installed.
Back to top
« Last Edit: Sep 9th, 2011, 7:02pm by CWatters »  
Thank User For This Post View members image gallery  
IP Logged
 
baz
Trade Member
*****
Offline

If it ain't broke, keep
fixing it until it is!

Posts: 258


Total Thanks: 0
For This Post: 0


Henley-on-Thames, United Kingdom
Henley-on-Thames
United Kingdom

Gender: male

Trade: Electrician



Re: Lighting earth question
Reply #2 - Sep 9th, 2011, 7:51pm
 
Just because there is a "earth" conductor does not mean that it is connected to earth.  You need to test it once the connections are made otherwise thee is no point.

By the way, the centre unsleeved conductor is called the cpc.
Back to top
 

Why is it that, when we stumble across a can of worms, instead of running for the door we find ourselves reaching for a can opener?
Thank User For This Post View members image gallery  
IP Logged
 