Oct 29th, 2011, 5:06pm
 
our landing light is switched by a ceiling mounted PIR, to stop the kids leaving it on all day.  

the sensor doesn't detect people until they are quite close to it, so i thought the answer would be to move it to one end of the landing and add another at the other end.

the sensor has 3 connections - live and neutral in, and a switched live out.    can you add an extra sensor by simply connecting them in parallel?
Back to top
 
Thank User For This Post WWW View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8815


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: internal PIR
Reply #1 - Oct 29th, 2011, 6:41pm
 
Yep, thats exactly what to do.

You could change the PIR for a microwave occupancy detector.  They are far more sensitive, less prone to false triggers, and balloon a larger area.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
Natedog
Full Member
***
Offline

Ask The Trades
Posts: 347


Total Thanks: 9
For This Post: 0


Swindon, United Kingdom
Swindon
United Kingdom


Re: internal PIR
Reply #2 - Oct 30th, 2011, 3:01am
 
Not heard of them, I'll look into them.  Thanks dude Smiley
Back to top
 
Thank User For This Post WWW View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print