Welcome, Guest. Please Login or Register
Welcome To Ask The Trades!
May 7th, 2024, 8:34am
Quote: The lottery is a tax on people who are bad at maths - Ambrose Bierce (1842)


Page Index Toggle Pages: 1
Send Topic Print
Baxi 105e dhw problems ???? (Read 2623 times)
martymac
GDPR opt-out









Baxi 105e dhw problems ????
Jan 7th, 2012, 6:22pm
 
Hello all,

I had no hot water yesterday and I indentified it as a diaphram problem.  I changed the diaphram, now I have. However it appears that the temp rises quickly to 80, eventhough the temp dial is set half way. The burner lights as normal and then cuts out for a couple of seconds then relights. This changes the temp from the taps. It seems to do this cycle as long as the taps are open. I have not noticed any warnings on the panel, all seems normal . CH is working as normal HELP!!!!
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Baxi 105e dhw problems ????
Reply #1 - Jan 8th, 2012, 11:26am
 
Blocked plate HX.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
martymac
Re: Baxi 105e dhw problems ????
Reply #2 - Jan 8th, 2012, 2:01pm
 
Will I be able to do this myself ? It seems really awkward to get to as its at the back of the boiler. What is the best way to clean it

many thanks


thanks
Back to top
« Last Edit: Jan 8th, 2012, 2:05pm by martymac »  
Thank User For This Post  
IP Logged
 