extractor fan question (Read 3508 times)
andyelbac
GDPR opt-out









extractor fan question
May 8th, 2012, 9:48pm
 
I recently moved into a new home with an extractor fan in the kitchen activated by a humidity sensor. The previous owner mentioned that it was recently installed but never worked and had never gotten round to calling the installer back. I checked it yesterday and the socket appears to be wired up and the fuse ok. However, when I removed the fan cover I noticed that although the live, nuetral and earth were connected to one side of the connector block, on the other side only the live and nuetral were connected. The earth was hanging loose, unstripped. As I know nothing about electrics I am loathe to connect up the earth even though that seems the sensible thing to do. I would like some professional advice on what to do. Thanks  Smiley
Back to top
 
 
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8815


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: extractor fan question
Reply #1 - May 8th, 2012, 9:52pm
 
Photo?

The earth not being connected would not cause it to not work.

The fan may have three connections on the terminal block, but none of them could be earth (often Red, Yellow, Black for example, none of which are earth).  The earth may not be needed and should be placed into a spare terminal block.

What make / model is the fan and humidistat?

Photos would help.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
andyelbac
Re: extractor fan question
Reply #2 - May 8th, 2012, 10:02pm
 
Hi,
thanks. I work away from home so will take a photo at the end of the week.
Back to top
 
Thank User For This Post  
IP Logged
 
The_Trician
Trade Member
*****
Offline


Posts: 7721


Total Thanks: 8
For This Post: 0


Gender: male

Trade: Electrician



Re: extractor fan question
Reply #3 - May 16th, 2012, 6:48pm
 
The fan is most likely double-insulated and the earth should be electrically isolated and 'parked' in a spare terminal.

It sounds like the humidistat hasn't been connected to the fan for some reason, but without more info I can't be certain.