32amp feeding 32amp??? (Read 3226 times)
Pesto
GDPR opt-out









32amp feeding 32amp???
Mar 24th, 2014, 7:45am
 
I have a 32amp mcb at the CU, running a feed to 2 sheds what are 32amp rated. I would like to be able to use them to there maximum capacity.

Are they both 32amp or are they half due to the 32amp mcb in the CU?

The shed are 30m away and feed with 10mm armoured cable.

Thanks
Back to top
 
 
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: 32amp feeding 32amp???
Reply #1 - Mar 24th, 2014, 5:09pm
 
10mm PVC/SWA can be rated higher than 32amp.  You could fit a 40 or 50 amp MCB on this cable, subject to cable installation methods.  How is the cable installed?  Loft voids, thermal insulation, clipped direct, trunking, grouped with others etc?

Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
Pesto
Re: 32amp feeding 32amp???
Reply #2 - Mar 24th, 2014, 10:41pm
 
The cable is connected to the main CU via a 32amp mcb. It then goes to the sheds external of the building on a wire about  30 meters from CU Tto sheds. It goes in to a switch box then the cable is spilt to feed both sheds. They are connected with a 3 pin caravan type thing. Rated at 32 amp.
Is the 32amp in the CU halved to feed both 16amp or do both get 32amp?
Back to top
 
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: 32amp feeding 32amp???
Reply #3 - Mar 25th, 2014, 6:29am
 
Well they obviously can't both use 32amp at once!  They could individually.

If there are 32amp sockets, you would not be able to upgrade the rating of the main MCB.  You could upgrade the main MCB and replace the splitting joint box with a second consumer unit, having a 32amp MCB for each shed.

What's going in the sheds?
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
Pesto
Re: 32amp feeding 32amp???
Reply #4 - Mar 25th, 2014, 9:17pm
 
1x 2500watt heater 1x740watt humidifier  and 2x 240watt bar heaters in each. There is  also 2x twin 5foot lights in each.
Do I have enlough amps?
Back to top
 
Thank User For This Post  
IP Logged
 
big_all
Global Moderator
Trade Member
Author
*****
Offline

heeelllooo
Posts: 5596


Total Thanks: 10
For This Post: 0


Gender: male

Trade: Joiner



Re: 32amp feeding 32amp???
Reply #5 - Mar 25th, 2014, 11:54pm
 
Quote:
1x 2500watt heater 1x740watt humidifier  and 2x 240watt bar heaters in each. There is  also 2x twin 5foot lights in each.
Do I have enlough amps?

 2500=10.4amp
740=3.1a
2x240w= 2a
2x5ftx2 =200w=0.8a
around 16.3333a

240w at 230v = approximately 1amp