Boiler change possibilities
Apr 25th, 2014, 10:03am
 
I've got a Potterton Suprima gas boiler at the moment which heats the hot water and stores it in an indirect cylinder. The central heating is via a pressurised mini-bore system which is no trouble at all. I've had it converted to remove the double valve and baffle pipe and each radiator has a flow and return at opposite ends (like they're supposed to!).

My boiler is getting a bit tired, so I'm thinking of replacing it with a combination. I know that this will get rid of the loft tank and the indirect, but will it be OK with the pressurised system, please, or is there a better way? Any strong preferences on the combo boiler itself?

TIA!

Ray
Back to top
 

At the younger end of the "old fart" scale.
Thank User For This Post WWW argee45 View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Boiler change possibilities
Reply #1 - Apr 25th, 2014, 1:46pm
 
Converted to remove the double valve and baffle pipe. whats that ??? Smiley

Rads can be connected TBOE or BBOE for best results but can be connected TBSE just as easily.

Most modern boilers can be connected to a sealed system.

A combi will almost certainly give you some drop in performance, but it is important the mains can deliver a consistent flow rate suitable for the choice of boiler.

Good boilers in my opinion is Intergas, but like most brands they benefit from being installed by an approved installer.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
woodsmith
Global Moderator
Trade Member
Author
*****
Offline


Posts: 4395


Total Thanks: 135
For This Post: 0


Gender: male

Trade: Joiner

Re: Boiler change possibilities
Reply #2 - Apr 25th, 2014, 3:32pm
 
thescruff wrote on Apr 25th, 2014, 1:46pm:
Converted to remove the double valve and baffle pipe. whats that ???


I assume it's the old single valve where the flow and return came to the same valve and one of them was extended into the rad with a bit of microbore.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
rgirling
Junior Member
**
Offline


Posts: 137


Total Thanks: 2
For This Post: 0


Crowborough, East Sussex, United Kingdom
Crowborough, East Sussex
United Kingdom

Gender: male



Re: Boiler change possibilities
Reply #3 - Apr 25th, 2014, 7:16pm
 
woodsmith was correct, it used to be just such a system. I was hoping for some clarity, but I'm more confused now. What's TBOE, BBOE and TBSE? What is meant by "some drop in performance"? In what respect - efficiency, delivery, capacity, something else?

I will have it professionally installed, I can't see anything in my question that suggests otherwise and I'm not a trade member. I was merely asking questions to see if it was even possible.

Ray
Back to top
 

At the younger end of the "old fart" scale.
Thank User For This Post WWW argee45 View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Boiler change possibilities
Reply #4 - Apr 25th, 2014, 7:47pm
 
TBOE top,bottom opposite ends.

BBOE bottom, bottom, oposite ends and the most popular.

TBSE top, bottom, same end not used much.

Hope that clears that up.

With any combi you need a good mains supply, and quite often the hot water performance is not as good as expected or as good as the existing but, it can be better and free up space at the same time, the installer should check the flow rate etc at peak and off peak times.

I didn't suggest you were installing it yourself and apologise if that was the impression.

yes you can change to a high pressure system without too many problems if any, the main thing would be to check Washing machine hoses etc are not old and worn, A ballvalve may be low pressure and need changing to high pressure but all obvious stuff your guy should be aware of.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
rgirling
Junior Member
**
Offline


Posts: 137


Total Thanks: 2
For This Post: 0


Crowborough, East Sussex, United Kingdom
Crowborough, East Sussex
United Kingdom

Gender: male



Re: Boiler change possibilities
Reply #5 - Apr 25th, 2014, 11:31pm
 
OK, thanks for that - much appreciated.

Ray