Which type of zone valve ? (Read 2601 times)
molerat
GDPR opt-out









Which type of zone valve ?
Mar 24th, 2005, 12:35am
 
My 20 year old Sunvic zone valves are dieing of old age so am about to replace them.  Which type are best for reliability and total lifespan, the rotating valve type as in Sunvic etc or the ball type like Honeywell, or are they much the same ?
Back to top
 
 
IP Logged
 
PEDANTICVINDICTIVEMAN
Trade Member
*****
Offline

Cant talk,old folks to
rip off and tanks to
pee in
Posts: 846


Total Thanks: 0
For This Post: 0


Gender: male

Trade: Not Specified

Re: Which type of zone valve ?
Reply #1 - Mar 24th, 2005, 7:03am
 
The rubber ball type are best in my opinion, but you may find your Sunvics need power to close whereas ball types are shut manually by a spring, so you may find it dificult to sort out on the wiring front
Back to top
 

If you cant find someone else to blame, run like fack.
Thank User For This Post  
IP Logged
 
molerat
Re: Which type of zone valve ?
Reply #2 - Mar 24th, 2005, 8:36am
 
Thanks for your opinion.  My old ones are spring return so no problems there.  Smiley
Back to top
 
Thank User For This Post  
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: Which type of zone valve ?
Reply #3 - Mar 24th, 2005, 12:45pm
 
I agree with PVM, in my opinion can't beat the Honeywell stuff. Easy to replace parts on too when the motor gives up.

btk
Back to top
« Last Edit: Mar 24th, 2005, 12:45pm by billythekid »  
Thank User For This Post  
IP Logged
 
Stoday
Re: Which type of zone valve ?
Reply #4 - Mar 30th, 2005, 1:13am
 
Sunvic make two types.

One which needs power  to hold it open, as others do, & uses a spring to close when the power is turned off. TTo operate this, you only need a programmer/thermostat with a normally open contact.

The other only uses power when it opens or closes; it does not use energy to hold it open. Needs a changeover contact to operate.