Venting for cooker hood / earthing ...
Apr 4
th
, 2005, 2:46pm
I plan to install venting from an existing cooker hood using flexible aluminum ducting (4" diameter).
Does this need 'earthing' in any way ?
If so, is this in terms of connecting it electrically to the earthed body of the cooker hood, or directly to the earth in the CU. How do you make the connections to the aluminum duct sections ?
Back to top
«
Last Edit: Apr 4
th
, 2005, 2:48pm by Lee_Elms
»
-- Lee
IP Logged
LSpark
Global Moderator
Trade Member
Author
Offline
Posts: 8069
Total Thanks: 3
For This Post: 0
London, UK
United Kingdom
Gender:
Trade: Electrician
Re: Venting for cooker hood / earthing ...
Reply #1 -
Apr 4
th
, 2005, 4:50pm
Hi Lee
In you're situation it's not normal to be able to earth or bond flexible pipes or ducting, I would reccomend bonding/earthing you're hood, if it isnt already, to the earth terminal in the cooker connection
Back to top
IP Logged
ban-all-sheds
GDPR opt-out
Total Thanks: 3
For This Post: 0
Re: Venting for cooker hood / earthing ...
Reply #2 -
Apr 4
th
, 2005, 5:56pm
The hood is an electrical appliance - it is made as a single item (ducting excepted) with lights and/or fan, and an electrical connection.
If it has an earth connection, it will be earthed automatically and appropriately when it is plugged/wired in.
If it does not, then surely by "bonding" the hood to the earth terminal of the cooker you are earthing the casing of a Class II appliance - something not recommended?
Back to top
IP Logged
LSpark
Global Moderator
Trade Member
Author
Offline
Posts: 8069
Total Thanks: 3
For This Post: 0
London, UK
United Kingdom
Gender:
Trade: Electrician
Re: Venting for cooker hood / earthing ...
Reply #3 -
Apr 4
th
, 2005, 6:04pm
Yep, it's probably all one unit, and if so it's best the earthing of the ducting is left well alone
Back to top
«
Last Edit: Apr 4
th
, 2005, 6:04pm by LSpark
»
IP Logged
Lee_Elms
Junior Member
Offline
Posts: 36
Total Thanks: 0
For This Post: 0
Gender:
Re: Venting for cooker hood / earthing ...
Reply #4 -
Apr 4
th
, 2005, 6:34pm
Thanks for the replies.
I suppose what I was thinking of was the general thing of earth bonding metallic items such as gas and water piping ... is there something which distinguishes this from the vent ducting ? (I think the cooker hood itself is a bit of a red herring).
Back to top
-- Lee
IP Logged
Lee_Elms
Junior Member
Offline
Posts: 36
Total Thanks: 0
For This Post: 0
Gender:
Re: Venting for cooker hood / earthing ...
Reply #5 -
Apr 4
th
, 2005, 6:37pm
To clarify, in case it's relevant: the ducting is joined to the hood via a plastic connection piece, so there isn't an electrical connection here.
Back to top
-- Lee
IP Logged
Pages: 1
(Moderator: Lectrician) - (Moderator Group: Board Moderator)
<
Previous Topic
|
Next Topic
>
Ask The Trades
›
DIY Forum
›
Electrical Questions
› Venting for cooker hood / earthing ...
Forum Jump »
Home
» 10 most recent Posts
» 10 most recent Topics
DIY Forum
- Electrical Questions ««
- Plumbing Questions
- Carpentry Questions
- Building Questions
- Painting, Decorating & Tiling Questions
- Alarms, Phones, Aerials, CCTV & Datacomms
Public Forum
- Just Talk
- Humour
- The Forum
- Trade Applications
Ask The Trades
» Powered by
YaBB 2.3
!
YaBB
© 2000-2008. All Rights Reserved.