Suprima 60 HE (Read 4273 times)
MrD
GDPR opt-out









Suprima 60 HE
Aug 3rd, 2009, 3:12pm
 
Dear all, I have a Suprima 60 HE boiler which keeps cutting out due to a circulation problem. What I must add is that I drianed the system to to fit more radiators and whilst the system was drained the boiler was activated for about 10 mins. I assumed that when the system was refilled and bled this error would go away but it hasn't. Any thoughts as to a cure?

Thanks
MrD
Back to top
 
 
IP Logged
 
Headrush
Trade Member
*****
Offline

Ask The Trades
Posts: 147


Total Thanks: 10
For This Post: 0


Nottingham, United Kingdom
Nottingham
United Kingdom

Gender: male

Trade: Plumber

Re: Suprima 60 HE
Reply #1 - Aug 3rd, 2009, 3:28pm
 
IF the system was run while dry, the pump bearings are probably shot to pieces.
Back to top
 
Thank User For This Post  
IP Logged
 
MrD
Re: Suprima 60 HE
Reply #2 - Aug 3rd, 2009, 5:28pm
 
Thanks for the reply but are you refering to the central heating pump? This was not run, only hot water was used which then initiated the boiler. The central heating pump still works without noise & vibration so I presume the pump to be ok.

I have had the central heating off for months now and the boiler cuts out whilst only heating the hot water.

Many thanks for any help/advice
Back to top
« Last Edit: Aug 3rd, 2009, 5:29pm by MrD »  
Thank User For This Post  
IP Logged
 
Headrush
Trade Member
*****
Offline

Ask The Trades
Posts: 147


Total Thanks: 10
For This Post: 0


Nottingham, United Kingdom
Nottingham
United Kingdom

Gender: male

Trade: Plumber

Re: Suprima 60 HE
Reply #3 - Aug 3rd, 2009, 7:38pm
 
Normally boilers don't ignite without a pump running somewhere.

Is it a combi? If so the pump does run when only using hot water. It pumps hot central heating water through a heat exchanger which heats the domestic hot water. If the pump is weak, the boiler will overheat and cut out.
Back to top
« Last Edit: Aug 3rd, 2009, 7:39pm by Headrush »  
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Suprima 60 HE
Reply #4 - Aug 3rd, 2009, 8:23pm
 
Is it a sealed system or open vent.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
MrD
Re: Suprima 60 HE
Reply #5 - Aug 4th, 2009, 11:37am
 
Its an open vented system.
Back to top
 
Thank User For This Post  
IP Logged
 
bill577
Re: Suprima 60 HE
Reply #6 - Aug 4th, 2009, 1:34pm
 
the suprima has a flow themistor so it would not fire without a flow of water through it, it sounds like you have air locked the boiler, the pump runs for central heating and /or hot water, did you refill the system with the 2 port valves open? one last thing if your working on your central heating switch it off .
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Suprima 60 HE
Reply #7 - Aug 4th, 2009, 1:41pm
 
Is there any manual air vents at high points, the cylinder coil for example.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 