gotExisting lintels (Read 2186 times)
archtech
GDPR opt-out









gotExisting lintels
Jun 28th, 2010, 1:30pm
 
I am preparing drawings for an extension to a dwelling and have come across a problem in detailing. A beam is required to support cavity wall above and floor, however this beam needs to be built into the existing wall of the house, and the location of this junction is right over an existing window. Assuming its not possible to cut through an existing lintel to allow the beam to slot in and it is definetly not an option to raise the level of the beam as ceiling heights are fixed, can anyone suggest a way around this??
Back to top
 
 
IP Logged
 
JerryD
GDPR opt-out









Re: gotExisting lintels
Reply #1 - Jun 28th, 2010, 8:27pm
 
This is a job for a structural engineer.  He will have to see the job, work out the loading and the span and then design a beam or beams to suit that application.  It sounds like you need a spreader beam of some description over this window.

You cannot rest a steel beam end onto a lintel, it is a point load and lintels are not designed for point loads.


btw, having one beam cut to shape and welded into the spreader means you are not adding to the beam overall height whereas stacking beams and spreaders does add height (hope that makes sense)
Back to top
« Last Edit: Jun 28th, 2010, 8:29pm by JerryD »  
 
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: gotExisting lintels
Reply #2 - Jun 29th, 2010, 7:53am
 
Sounds like you need a T shape beam with part replacing the lintel. I'm sure that must have been done a few times before now.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
JerryD
Re: gotExisting lintels
Reply #3 - Jun 29th, 2010, 6:39pm
 
'having one beam cut to shape and welded into the spreader' ........................that's a T shaped beam, we use this method a lot.  On site welding costs about £60 in addition to the steel cost.