Standard British Inline Wiring Question (Read 4324 times)
fighterflea
GDPR opt-out









Standard British Inline Wiring Question
Jan 5th, 2013, 6:56am
 
I am replacing a switch for a table top appliance which has 4 internal contact points.  Here in the U.S. switches conventionally have 2.  I think the switch to be replaced is from a Commonwealth country.  Am I correct in assuming that conventional British wiring of switches for table top lamps  and the like have 4 contact points?  (I've already spliced the wire and for reasons I won't go into prefer not to replace it and start over with wire and switches available to me here in the U.S.)

I'm ready to order a switch from the UK but am uncertain whether the inside will reveal 2 or 4 contact points.  Can someone shed light on this matter, so to speak?
Back to top
 
 
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8815


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Standard British Inline Wiring Question
Reply #1 - Jan 5th, 2013, 7:57am
 
Not sure what you mean by 'contact point'.  I assume this means terminal?  Most inline switches in the UK have a single switch pole, having two terminals.  Some include seperate terminals to loop the neutral and earth.

Going by the picture on this site, this has a looping earth terminal, and two pole switching (so 4 terminals, or 4 contact points).

http://www.collingwoodlighting.com/cnb/shop/collingwood?productID=682&op=catalog...

Image 177   
Back to top
« Last Edit: Jan 5th, 2013, 8:02am by Lectrician »  

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
fighterflea
Re: Standard British Inline Wiring Question
Reply #2 - Jan 5th, 2013, 8:11am
 
This is very useful and much appreciated.  In the U.S. we actually run part of the cord intact through the switch while the other part is cut and connected to contact points.  From what you loaded, it appears that that is not how it is done in the U.K.  Am I right?
Back to top
 
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8815


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Standard British Inline Wiring Question
Reply #3 - Jan 5th, 2013, 8:48am
 
There are many different switches available from many manufactgurers, some have a a double pole switch (as above), some have terminals to joint the un-switched cores, and some only have the single pole switch and you leave the inner cores uncut, as you say.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
fighterflea
Re: Standard British Inline Wiring Question
Reply #4 - Jan 5th, 2013, 11:32pm
 
Again, thank you very much for your timely, helpful response.  I come up at these problems pretty much self taught and I'm not a very good teacher.  Found what I needed and have made the order.
Back to top
 
Thank User For This Post  
IP Logged
 