Running 2 x 3 gang sockets off a consumer unit (Read 3429 times)
morgaf02
GDPR opt-out









Running 2 x 3 gang sockets off a consumer unit
Mar 4th, 2013, 9:27pm
 
Im normally pretty good with electrics, but need a bit of advice.

Im having some bespoke entertainment furniture installed soon and i need to rearrange the plug sockets.  I was looking at running a spur off of an existing 2 gang socket but am unable to do so as the existing one is already a spur.  

As the consumer unit is near (under stairs cupboard) to where i want the sockets can i run 2x 3 gang sockets straight off of the consumer unit?  There are spare rcd's on the unit.

Any help is appreciated.

Thanks.
Back to top
 
 
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Running 2 x 3 gang sockets off a consumer unit
Reply #1 - Mar 5th, 2013, 6:48pm
 
Yes, 2.5mm² from a B20 MCB or 4mm² on a B32 MCB.  These MCB's should have RCD protection.

Can you take a photo of the Consumer Unit as it is?
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
morgaf02
Re: Running 2 x 3 gang sockets off a consumer unit
Reply #2 - Mar 6th, 2013, 9:43am
 
Thanks for getting back to me.  Here are a couple of pics.

Image 1Image 2
Back to top
 
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Running 2 x 3 gang sockets off a consumer unit
Reply #3 - Mar 6th, 2013, 5:00pm
 
You would need to get a wylex B20 or B32 MCB and fit it to the RCD side of that board (the very far left empty way).  You cannot use the B6 MCB which is empty - it is too small, and on the wrong side of the RCD.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
morgaf02
Re: Running 2 x 3 gang sockets off a consumer unit
Reply #4 - Mar 6th, 2013, 8:01pm
 
Thank you for the help.  Much appreciated.  Grin
Back to top
 
Thank User For This Post  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print