Re: Wet Underfloor heating installation (renovation)
Reply #8 - Aug 20th, 2018, 5:16pm
 
The heating will be on for around 8-12 hours in one cycle a day when needed providing constant heat. Obviously it won't be needed during the summer months just like I haven't used my heating this year in my old house.

I didn't think the screedboards would give much but I will need to check that out if that is the case. They are better conductors of heat than chip/ply which is why I had opted for them but if they're going to cause issues and given their price I might just look at alternatives.

The house is going to be fully insulated throughout and at present only has  2 radiators in the whole house. The house is empty so taking up boards etc. isn't an issue. There was one in the hallway and one in the living room. Upstairs were electric storage heaters which have now been taken out.
Back to top
 
Thank User For This Post  
IP Logged
 
big_all
Global Moderator
Trade Member
Author
*****
Offline

heeelllooo
Posts: 5596


Total Thanks: 10
For This Post: 0


Gender: male

Trade: Joiner



Re: Wet Underfloor heating installation (renovation)
Reply #7 - Aug 20th, 2018, 12:29am
 
ok my thought
longer lasting means less efficient
you are far far better without mass to slow down the heating process
in general underfloor needs constant use rather than say 2 cycles a day
if you surround the heating elements in mass you are not warming the room when you need it but sharing the very under powered elements with a mass that will give out heat perhaps 3 or 4 hours after you need  it
there is no way off getting more than 100% off energy back the best way is full heat when you need it in general this is radiators in room not underfloor that unless you house is very very well insulated underfloor is not an sensible option
Back to top
« Last Edit: Aug 20th, 2018, 12:33am by big_all »  

big all ---------------  we are all still learning
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 5926


Total Thanks: 122
For This Post: 0


Gender: male

Trade: Plumber



Re: Wet Underfloor heating installation (renovation)
Reply #6 - Aug 19th, 2018, 8:58pm
 
This is what you should be looking at but you really need to strengthen the joists from aboveImage 6
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5118


Total Thanks: 55
For This Post: 1


Gender: male

Re: Wet Underfloor heating installation (renovation)
Reply #5 - Aug 19th, 2018, 6:39pm
 
Can you safely tile over the 20mm screedboard? I'd be concerned about it flexing when people walk on it.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Newkiebrown
Junior Member
**
Offline

Ask The Trades
Posts: 8


Total Thanks: 0
For This Post: 0


Newcastle, United Kingdom
Newcastle
United Kingdom

Gender: male



Re: Wet Underfloor heating installation (renovation)
Reply #4 - Aug 19th, 2018, 1:21pm
 
I wanted a longer lasting heat retainer rather than using the plates which then creates an air void to waste some of the heating. That was the only real reason for not going down the plate route. The only people I know that have it installed either have electric for additional heat or in screed which produces a longer lasting heated area. I will find the link and post it when I am back home. Also a lot of the pre-formed systems use a 200mm gap whereas I want a 150mm gap in some areas due to it being the only heat source throughout the house
Back to top
 
Thank User For This Post  
IP Logged
 
woodsmith
Global Moderator
Trade Member
Author
*****
Offline


Posts: 4277


Total Thanks: 109
For This Post: 0


Gender: male

Trade: Joiner

Re: Wet Underfloor heating installation (renovation)
Reply #3 - Aug 19th, 2018, 10:43am
 
If you google suspended floor underfloor heating systems you will find lots of proprietary methods of fitting ufh normally involving fitting a tray to support the pipes and I would recommend using one of these.

I would be interested to know where you found someone recommending pouring screed over insulation wedged between joists, can you post a link?
Back to top
 


Thank User For This Post View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8765


Total Thanks: 103
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Wet Underfloor heating installation (renovation)
Reply #2 - Aug 19th, 2018, 10:41am
 
Any reason you're not opting to go for the metal heat spreader plates as opposed to the screed?

...

...

...

...

This shows your method too, the screed between joists.

...

https://underfloorheating-direct.com/confused-water-heating-between-joists-245-w...
Back to top
« Last Edit: Aug 19th, 2018, 10:44am by Lectrician »  

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 5926


Total Thanks: 122
For This Post: 0


Gender: male

Trade: Plumber



Re: Wet Underfloor heating installation (renovation)
Reply #1 - Aug 18th, 2018, 9:06pm
 
Have to wait till next week for loads of questions.

Really don't like the sound of what you are trying to do.

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Newkiebrown
Junior Member
**
Offline

Ask The Trades
Posts: 8


Total Thanks: 0
For This Post: 0


Newcastle, United Kingdom
Newcastle
United Kingdom

Gender: male



Wet Underfloor heating installation (renovation)
Aug 18th, 2018, 2:26pm
 
Hi all,

I am new to this site.

I am planning on installing Wet UFH in a house I am renovating and want it to be the main source of heating. There will be a radiator in the bathroom and one in the hallway potentially but that's it, I am hoping. The house is a 1920's semi detached property which needs some serious updating. It has a 32kw boiler and cavity wall insulation. I will be putting insulation in the loft as what is in there looks like it was put in by someone who was either blind or blind drunk (I have visions of someone spinning round quickly and letting go of the insulation at random intervals).

I have been doing a quite a bit of research and have come up with the following as my idea. The house has 130mm joists so I am limited in what I can achieve within this.
130mm joists
Space utilised as follows:

25mm x 25mm battens running along the joist bottom.
80mm PIR Insulation laid on top of the battens.
membrane laid over insulation and joists
25mm flowing screed incorporating the 16 or 20mm UFH pipes throughout the house.
This will make use of the 130mm joist space.
On top of this I intend to put 20mm screedboards instead of plywood floor
9mm tiles on top of these (tiles are suitable for UFH).


I have a few questions initially about it before I take my plan any further but more will follow as I get into it, no doubt.

1. Will 80mm of thermal insulation supported by 25mm battens along the bottom of the joists be supportive enough for 25mm of flowing screed on top. It will be poured purely between the joists which are about 350-370mm apart on the ground floor of the house and 130mm deep each. The screed is thinner than is recommended but it will not take much, if any, load as the screedboards will do this on top of the joists.

2. Would 20mm piping make much more of a difference in heat terms compared to 16mm pipe. Both will fit within the 25mm of screed which I am planning to lay on top of the insulation.

3. Would I benefit much from using a bond to "fix" the screed to the screedboards or would this help encourage cracks/splits due to more movement in the screedboards that the screed lying on insulation by itself.

4. Would 20mm screedboard 9mm tiles (few mm for  adhesive) and 25mm screed be sufficient to give a nice even heat across the floor without it being too cold or hot.

5. For best results in heat transmission upward should I ensure a complete layer of adhesive (as much as possible rather than notched) for the tiles so as to remove as much air between the adhesive and tile base as possible. I presume this will make getting them level much harder with a lot less "give" in the tile adhesive.

I apologise if this should go in another forum area but wasn't sure which it should in covering numerous trades.
Back to top
 