Causes of boiler noises and pumping over? (Read 15760 times)
oggy
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 8


Total Thanks: 0
For This Post: 0



Re: Causes of boiler noises and pumping over?
Reply #17 - Jan 17th, 2005, 12:39am
 
It's an Orion Fanfare 60Si, if that helps!

The problem was happening regularly 20 mins or so after it first came on, but would also do it later on in the evening too.

However it's been quiet for a good few days now since the boiler was reduced to 1. Also the f/e tank level is currently lower than it had been as the supply to this is  still turned off!

Wouldn't circulation problems lead to cold spots in the system? Everything is lovely and hot at the moment! And the motorised valves seem to be working ok.

So it sounds like I need to get a Corgi in to check out the gas valves....
Back to top
 
Thank User For This Post  
IP Logged
 
woodsmith
Global Moderator
Trade Member
Author
*****
Offline


Posts: 4395


Total Thanks: 135
For This Post: 0


Gender: male

Trade: Joiner

Re: Causes of boiler noises and pumping over?
Reply #18 - Jan 17th, 2005, 8:18am
 
Oggy wrote;

"What level of water should there be in the tank? Mine was about 2/3 full with the end of the overflow dipping down below the surface"

Do you think that having the overflow pipe dipping into the water in the tank may cause a problem? As the heating cools water will be drawn up the overflow pipe and may be causing some sort of air lock which clears when the heating gets up to a certain temperature?

Just a thought  ???

Keith
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: Causes of boiler noises and pumping over?
Reply #19 - Jan 17th, 2005, 12:11pm
 
[quote author=woodsmith  link=1105056479/15#18 date=1105949930]Oggy wrote;

"What level of water should there be in the tank? Mine was about 2/3 full with the end of the overflow dipping down below the surface"

Do you think that having the overflow pipe dipping into the water in the tank may cause a problem? As the heating cools water will be drawn up the overflow pipe and may be causing some sort of air lock which clears when the heating gets up to a certain temperature?

Just a thought  ???

Keith [/quote]
no keith, he meant the actual tank overflow, not the expansion pipe from a cylinder. It fine to have the overflow in this way, in fact thats how a by-law 30 kit comes. as the tank level drops all that will be drawn from the overflow is air, to the tank space. Still could be airlock, although not for this reason.
Back to top
« Last Edit: Jan 17th, 2005, 12:11pm by billythekid »  
Thank User For This Post  
IP Logged
 
woodsmith
Global Moderator
Trade Member
Author
*****
Offline


Posts: 4395


Total Thanks: 135
For This Post: 0


Gender: male

Trade: Joiner

Re: Causes of boiler noises and pumping over?
Reply #20 - Jan 17th, 2005, 6:40pm
 
Thanks BTK,

Ah well, would have been a good idea if I hadn't got my overflow mixed up with the expansion pipe Embarrassed Roll Eyes
Back to top
« Last Edit: Jan 17th, 2005, 6:40pm by woodsmith »  
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Causes of boiler noises and pumping over?
Reply #21 - Jan 17th, 2005, 7:27pm
 
http://www.partsarena.com/baxi/

Fault chart can be found abovelink.

Does the main burner turn off before a flow temperature of 60c when on 1 ?

No; Disconnect main solinoid lead, does the main burner shut down ?

Yes change boiler thermostat,
No change gas valve.

scruff
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
oggy
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 8


Total Thanks: 0
For This Post: 0



Re: Causes of boiler noises and pumping over?
Reply #22 - Jan 18th, 2005, 11:51pm
 
Thanks for the help guys, I'll investigate further soon.....