I intend putting longer 2 core round flex on a couple of my power tools,the heaviest i can get is 0.75 mm ,however this does not seem as thick as what is already fitted.Will this be ok on drills or handplaners upto 800 watts?
Back to top
 
 
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: Size of flex
Reply #1 - Apr 15th, 2005, 1:00am
 
Quote:
Will this be ok on drills or handplaners upto 800 watts?

Yep, the differences in flex sizes can be difficult to tell as there so close in size, what’s more the PVC can be a different thickness on different cables, but if it's marked 0.75mm on the cable you're good to go.

Do try to keep the flex as short as is possible as this is recommended practice due to tripping hazards and possible damage to cables.

for you're own reference, flexible cables of the following sizes have the following current carrying capacity's..

0.5mm - 3A (690W)
0.75mm - 6A (1,380W)
1mm - 10A (2,300W)
1.25mm - 13A (2,990W)

But these are strictly for short lengths and only for portable appliances, Flex should not be used for doing fixed wiring in the house as it's not designed or suitable for this.

Back to top
« Last Edit: Apr 17th, 2005, 2:26am by LSpark »  
Thank User For This Post View members image gallery  
IP Logged
 
Raptor
Re: Size of flex
Reply #2 - Apr 15th, 2005, 7:02pm
 
Thanks for that info,couple of tools only have leads of about 6-8 ft ,will replace them with about 15 ft to be able to work around the room without an extension cable.l
Back to top
 
Thank User For This Post  
IP Logged
 
JerryD
Re: Size of flex
Reply #3 - Apr 15th, 2005, 7:12pm
 
[quote author=L.Spark  link=1113518952/0#1 date=1113523211]


Do try to keep the flex as short as is possible as this is recommended practice due to tripping hazards and possible damage to cables.


[/quote]

I prefer longer cables actually.  When up a step ladder you're not trying to balance the extension lead drum up there with all the other paraphernalia you need to hammer on a light fitting  Roll Eyes

btw, my Fein Multimaster has the longest lead I've ever seen on a power tool, it's brilliant.  Cheesy
Back to top
 
Thank User For This Post  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: Size of flex
Reply #4 - Apr 16th, 2005, 2:08am
 
My drills have invisible leads, they call them battery drills  Grin
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
santacruz
Re: Size of flex
Reply #5 - Apr 16th, 2005, 7:13pm
 
[quote author=L.Spark  link=1113518952/0#1 date=1113523211]
Yep, the differences in flex sizes can be difficult to tell as there so close in size, what’s more the PVC can be a different thickness on different cables, but if it's marked 0.75mm on the cable you're good to go.

Do try to keep the flex as short as is possible as this is recommended practice due to tripping hazards and possible damage to cables.

for you're own reference, flexible cables of the following sizes have the following current carrying capacity's..

0.5mm - 3A (690W)
0.75mm - 6A (1,380W)
1mm - 10A (2,300W)
1.25mm - 13A (2,990W)


[/quote]

Hey LS - so when people start rewiring their final rings  in 1.25mm flex csa (13A) that's OK is it! lol

For you starter for 10 the Zs reading will be about ....

Back to top
 
Thank User For This Post  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: Size of flex
Reply #6 - Apr 17th, 2005, 2:24am
 
Yikes, you're a clever girl santacruz, I must stick a note to remind people flex is only suitable for portable appliances in general, else there's going to be a rats nest somewhere  Grin