oil combi DHW problem (Read 1161 times)
trevtherose
Newbie
*
Offline

I love YaBB 1G - SP1!

Posts: 1


Total Thanks: 0
For This Post: 0



oil combi DHW problem
May 8th, 2005, 12:12pm
 
Hi, I've had an oil-fired combi (worcester heatslave12/14) installed 2 years. Recently when the hot water only setting is selected this also heats up all the rads even though the room thermotat is set to 0. Any ideas ?

Trev
Back to top
 
Thank User For This Post  
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: oil combi DHW problem
Reply #1 - May 8th, 2005, 4:01pm
 
check your motorised/diverter valves, sounds like the one "blocking off" the heating rads is stuck open.  Could also be faulty stat keeping it open, amongst other things. Start with the motorised valves...