12v lights
Nov 10th, 2004, 8:28pm
 
I've got a set of elv halogen lights run inside a wall for a feature wall holes thingy, transformer type.
They used to be wired up to the ring(coz those were the first cables i came across) in 6mm(coz that was the only cable i had) but when we got re-wired recently, the sparks routed the cables differently and didnt reconnect the lights as they werent originals(coucil property).
now I'd like to take the feeds to these lights from one of the existing ceiling roses downstairs but i dont have a clue how to do it, if the downstairs light is switched that would mean no hot wire when the light is off, so no feed to the 12v ones right?
Theres another light close by that runs off a (3-way?) setup, 2 switches for one bulb. I understand that this should have an always on cable, though doesnt which wire is on depend on how the switches are switched?
I suppose my question is, where do i take the feed wire to the lightswitch for the 12v ones from? can it be from an existing ceiling rose or do i need to run a new feed from the CU? I want these lights to be switchable independantly from the other lights downstairs.
any help much appreciated.
Back to top
 
Thank User For This Post  
IP Logged
 
tellondon
Re: 12v lights
Reply #1 - Nov 10th, 2004, 8:58pm
 
Depends how your lighting has been wired Billy, If its in twin + earth you should have a permanent Live at every ceiling rose, so you could get your feed for your ELV lights from the ceiling rose but how was you planning to switch them?
If you have a conduit system in your house Billy it might not be so easy as the permanent live would be at the switch and then you would have to pick up a neutral from the ceiling rose and break into the conduit
Try and get more information for us and let us know how you was planning to switch your ELV lights

Back to top
 
Thank User For This Post  
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: 12v lights
Reply #2 - Nov 10th, 2004, 9:12pm
 
atm they are switched from a lightswitch in the stud wall.
i ran a wire from the old ring to the switch in the wall then back up to the transformer,  taking the neutral direct from the ring. the wiring is still there so hopefully just need to move it from the old j-box i put in to a ceiling rose. does this help. The stud wall i built myself with the lights inside it. I dont know how the house lights are wired atm whether its t+e or not. theres no conduit in the house though so i can get into everything easily enough.
Back to top
 
Thank User For This Post  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: 12v lights
Reply #3 - Nov 11th, 2004, 1:15am
 
Borrowing neutrals is dangerous Billy, might need to re-think a better arrangement for the supply and switching of them lights, which I gues is what your doing at the moment  Smiley
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: 12v lights
Reply #4 - Nov 11th, 2004, 7:30am
 
...

Hope this helps.

Earths ommited for clarity.

Hope your ceiling rose has the above terminals, middle terminal is constant live.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
sparkyjonny
Re: 12v lights
Reply #5 - Nov 11th, 2004, 12:10pm
 
[quote author=L.Spark  link=1100118522/0#3 date=1100135740]Borrowing neutrals is dangerous Billy, [/quote]

It's not necessarilly a borrowed neutral if the switch where you are taking your phase from is on the same circuit as the ceiling rose where you get the neutral - this is standard conduit wiring.

Do you have a nearby socket which you could use to feed a spur unit (with 2.5mm T&E), with a 3A fuse?
Ideally it should come from the lighting circuit, but there's nothing wrong with this arrangement.
Back to top
« Last Edit: Nov 11th, 2004, 12:11pm by sparkyjonny »  
Thank User For This Post  
IP Logged
 
The_Trician
Trade Member
*****
Offline


Posts: 7721


Total Thanks: 8
For This Post: 0


Gender: male

Trade: Electrician



Re: 12v lights
Reply #6 - Nov 11th, 2004, 12:43pm
 
Its 'borrowing' in my book - He's taken it off the Ring for lighting purposes.

TT
Back to top
 

Thats the trouble with a colostomy - you can never find the shoes to match the bag.......
Thank User For This Post  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: 12v lights
Reply #7 - Nov 11th, 2004, 1:07pm
 
[quote author=sparkyjonny  link=1100118522/0#5 date=1100175030]

It's not necessarilly a borrowed neutral if the switch where you are taking your phase from is on the same circuit as the ceiling rose where you get the neutral - this is standard conduit wiring [/quote]

But It's not....
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
sparkyjonny
Re: 12v lights
Reply #8 - Nov 11th, 2004, 4:30pm
 
Trician,
Sory - I was referring to Tellondon's post - I think you were looking at Billy's reply!
Back to top
 
Thank User For This Post  
IP Logged
 
tellondon
Re: 12v lights
Reply #9 - Nov 11th, 2004, 7:20pm
 
Just to clarify , i meant take a neutral from the same lighting circuit
Borrowing a neutral from a different circuit would be dangerous
I didnt realise Billy had done that though, although i did notice that he had taken the supply from a power circuit without fusing it down which isnt good
Back to top
 
Thank User For This Post  
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: 12v lights
Reply #10 - Nov 12th, 2004, 12:04am
 
ok, the installation was from the ring before, i am changing it to the lighting circuit coz the cables i had connected to are dead now, so both live and neutral are gonna come from the ceiling rose. before all wires came off the ring connected with terminal blocks similar to the picture(omitting the ceiling rose and putting in a T+E instead) I told the spark who did the rewire how i'd done it, he said it wasnt too bad since i'd used 6mm.(mentioned something about 32amps or something with a strange look) Its all past tense now anyhow coz its changing Wink
one thing i noticed was the switch has only 2 connection points, in and out, no L2. Should i get another kind of switch(even though thats not used.)? I know i am showing myself up here! but hey if you dont ask....
The lights are indeed run t+e so i'll be following the picture i guess....
Back to top
« Last Edit: Nov 12th, 2004, 12:04am by billythekid »  
Thank User For This Post  
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: 12v lights
Reply #11 - Nov 12th, 2004, 12:07am
 
next question, what size cable do i use coming from the existing circuit to the trannie? still only havve 6mm here(unless i can did out some of the old dead stuff from undfer the floor. isnt there good scrap money in that?
Back to top
 
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: 12v lights
Reply #12 - Nov 12th, 2004, 7:41am
 
Use 1mm/sq through out.

If you have an L2 at the switch, just leave it empty.

Copper is only good for scrap if you are prepared to strip it back, and this is only really viable in my eyes on 50mm/sq and above  Wink
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: 12v lights
Reply #13 - Nov 12th, 2004, 7:54am
 
As lecc said really, don't use 6mm for your lights tho, it's highly unlikely it wont fit in your wiring terminals, also a 1-way switch has Common + L1

a 2-way switch has Common + L1 + L2

You only need a one-way switch for this, 2-way is for upstairs landing lighting where you have a switch downstairs and a switch upstairs...

1mm Twin+Earth cable would be ok to use
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: 12v lights
Reply #14 - Nov 12th, 2004, 8:54am
 
thanks very much everyone for your help, will crack on....
Back to top
 
Thank User For This Post  
IP Logged
 
The_Trician
Trade Member
*****
Offline


Posts: 7721


Total Thanks: 8
For This Post: 0


Gender: male

Trade: Electrician



Re: 12v lights
Reply #15 - Nov 12th, 2004, 5:23pm
 
Hey Billy - Where's yer moggie gone mate?

My dog hasn't had it I can assure you.
Nowt worse than losing your pussy  Wink Wink

Grin Grin Grin Grin Grin Grin

TT
Back to top
 

Thats the trouble with a colostomy - you can never find the shoes to match the bag.......
Thank User For This Post  
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: 12v lights
Reply #16 - Nov 13th, 2004, 1:00am
 
toothache is worse.
Dunno where the cat went, if seen post a picture of it, the stranger the better Wink